Serving the HVAC industry since 1992
Call: (800) 435-2526Email SearchMenu
  • Improves comfort by eliminating over-cooling and over-heating
  • Saves energy by automatically directing over-conditioned air flow to areas still needing the conditioned air
  • Saves energy by reducing airlfow to spaces not being used
  • Damper slips into diffuser collar between the flex duct drop and ceiling diffuser, or in flex duct run
Unit of Measure

Specifications

Diameter

N/A 12 in

Operation

N/A Variable position, 0 to 5 VDC control

Torque (Open and Close)

N/A 80 in·oz5 in·lb
Rotation Angle1 N/A 90 º

Adjustable Positioning

N/A Damper position is controlled by the manual wall control, occupancy sensor or zoning panels.

Adjustable Close Position

N/A Mechanical cam in actuator can be set to limit close position from approximately 50% closed to fully closed.

Operate Time from Fully Open to Fully Closed

N/A 5 s

Noise Level

N/A Very Quiet

Light Emitting Diode (LED) for Open

N/A Green

Light Emitting Diode (LED) for Close

N/A Red

Electrical Power Alternating Current (AC) Voltage

N/A 24 V

Running Electrical Power Current

N/A 2.6 V·A

Holding Electrical Power Current

N/A 1 V·A

Power Connection

N/A Screw terminals, COM and 24 VAC for power

Multiple Dampers

N/A A wall control or occupancy sensor can control up to 6 dampers.

Application

Application

N/A
  • Control air flow from a ceiling diffuser, register or grill.
  • Wired control using the MWC Manual Wall Control or OSL Occupancy Sensor

Features

Features

N/A
  • Dampers are controlled by three wires from the damper actuator to the MWC Manual Wall Control or OSL Occupancy Sensor
  • Multiple dampers can be controlled by one MWC or OSL
  • Multiple dampers can be powered by a single 24 VAC transformer installed in the ceiling space
  • Mechanical Closed position limit can be used to insure minimum air flow

Note

Note

N/A Made in the USA.
  • 1 Operation at 1-inch static pressure.
^